We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for Enteral Feeding Spike , Feeding Tube Bags , Tube Feeding By Gravity , Being a young increasing organization, we might not the best, but we have been trying our best for being your very good partner.
OEM China Purpose Of Nasogastric Tube Feeding Companies Factory - Enteral feeding pump – LINGZE Detail:

Video

Product Detail

Enteral feeding pump (W/O heating system)

Main features

Oversize LCD for easy operation

Autoperfusion improves work efficiency

More humanization design

Safety

Delivery deviation less than 10%

Various alarm functions

Characteristic

Infusion rate range 0-400ml/h(increment 1ml/h), with error less than ±10% Temperature +10℃~+30℃
Task setting range 0-3000ml (increment 1ml) Relative humidity  30%~75%
Dosing range 0-3000ml (increment 1ml) Air pressure 700hpa~1060hpa
Interval setting range 1h-24h (increment 1h) Language English/Chinese
Total infusion volume 0-9999ml (minimum 1ml displayable) Power supply 100V-240V, 50/60HZ
Clock

Built-in 24h time clocking

Memory function 24h
Alarm volume

Low, middle and high

Battery cruising

capacity

Non-stop 24h under the pump operating at an infusion rate of 25ml/h
Screen LCD Economic mode Screen off mode
Battery

4 chargeable lithium cells, DC8.4V

Service life 5 years

Efficient & Intelligent

1.Choose continuous or intermittent infusion mode, the infusion mode for patients with different gastrointestinal functions which will help patients to carry out nutrition feeding as soon as possible
2.Screen off function during operation, night operation does not affect patient’s rest; the running light and alarm light indicate the pump running status when the screen is off
3.Add engineering mode, carry out speed correction, key test, check running log, alarm
Code
4.The maintenance interface realizes program update

Safety upgrade

1.Comply with electromagnetic compatibility standards and medical electrical appliances safety standards, and enhance the ability to resist electromagnetic interference
2.The internal layout of the main engine is rearranged, the pump door is added, and the overall sealing performance of the main engine is strengthened to prevent the nutrient solution from accidentally entering the main pump
3.The integrated design of the power supply seat and the connector on the main unit are dedicated, and cannot be interchanged with other brands to ensure that the main unit uses a power supply that meets the medical electrical safety standards
4.Equipped with a waterproof sound outlet to increase the volume of the speaker, and notify the medical staff of the feeding pump alarm in time
5.All alarm sounds are continuous. After the alarm, the alarm will stop only after human intervention, such as “task completed, pause timeout” alarm
6.With “pre-perfusion completed, power cord off” alarm, suitable for hospital use.

Easy Operation

1.A liquid outlet is added under the heater compartment to prevent nutrient solution from being stored in the heater compartment and is easy to clean
2.The key structure design has passed 10,000 life inspections (internal testing by the company)
3.The solid infusion clamp structure can be repeatedly disassembled and assembled, and it is portable
4.With the prompt function: “Do not heat under the battery, recalculate the task, please set the parameters”, use it at a glance
5.With the function of clearing parameters, simplify the setting process


Product detail pictures:

OEM China Purpose Of Nasogastric Tube Feeding Companies Factory - Enteral feeding pump  – LINGZE detail pictures

OEM China Purpose Of Nasogastric Tube Feeding Companies Factory - Enteral feeding pump  – LINGZE detail pictures


Related Product Guide:

While using the "Client-Oriented" organization philosophy, a rigorous top quality command process, highly developed production devices and a potent R&D workforce, we normally provide high quality products, outstanding solutions and aggressive charges for OEM China Purpose Of Nasogastric Tube Feeding Companies Factory - Enteral feeding pump – LINGZE , The product will supply to all over the world, such as: Georgia, Victoria, Uzbekistan, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We now have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.
  • Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Olivia from Costa Rica - 2018.06.18 17:25
    Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Amber from UAE - 2017.02.28 14:19
    Write your message here and send it to us